Microchannel Plate with Solid Border MCP B 25-6

Microchannel Plate is intended for operation in vacuum inside Image Intensifier Tubes as a multi-channel secondary-electron multiplier of electron images.

Alternative specification may be made on customer’s order.

Size-shape factors

Parameter

Dimension

Value

Plate Diametermm32.8
Active Area Diametermmnot less than 26
Plate Thicknessmm0.3
Channel Diameterum6
Center-to-Center Spacingum8
Bias Angledegrees5
Electrical and Image Characteristics

Parameter

Dimension

Value

Electron Gain at 800 V-1000
Resistance×108 Ohms1 - 3
Minimum Limiting Resolutionlp/mm75
Maximum Dark Current Density×10-14 A/cm25
Noise factor, typical value-2.5
Open Area Ratio%not less than 59

MTTF (mean time to failure) – not less than 7500 hrs.

Absolute maximum ratings

Description

Units

Limiting Value

Operating VoltageVне более 1000
Field StrengthV/mm10000
Input Current Density×10-8 A/cm21
Output Current Density×10-7 A/cm24

Vacuum Bakeout Limiting Temperature: 440° С during not more than 6 hrs. at 5×10-6Torr.

Warranties:

Shelf-life: the MCP shall be stored in container provided by the manufacturer during 6 months, in vacuum (1.33×10-3 Pa) during 1 year or 15 years as a part of an image intensifier tube. The shelf-life is to be calculated from the acceptance date of manufacturer’s quality inspection, and in a case of reacceptance from the reacceptance date.